<acronym id="suig6"><center id="suig6"></center></acronym><acronym id="suig6"><center id="suig6"></center></acronym>
<sup id="suig6"><div id="suig6"></div></sup>

活塞并联机组

  • 发布日期:2018-06-04

    访问人气:572

  • 联系电话:13317326966
  • 简介:
    低温单级/活塞并联机组中温单级/活塞并联机组型号压缩机蒸发-40℃蒸发-37…
  • 免费获取报价

    低温单级/活塞并联机组

    低温单级/活塞并联机组


    中温单级/活塞并联机组

    中温单级/活塞并联机组


    型号压缩机蒸发-40℃蒸发-37℃蒸发-35℃蒸发-30℃蒸发-25℃蒸发-20℃
    匹数型号数量制冷量功率制冷量功率制冷量功率制冷量功率制冷量功率制冷量功率
    JX220SL204PES-1227.017.669.808.5411.309.2016.3010.9221.6012.7828.0014.78
    JX224SL244NES-1428.509.2011.9010.4214.0011.2620.5013.4427.1015.7035.6018.02
    JX230SL304HE-18212.0611.7114.6213.5618.2014.7825.4017.8234.0020.7845.1023.70
    JX240SL404GE-23213.2014.3317.2016.4420.3617.9029.3021.4839.6024.9252.2027.78
    YX345SL454HE-18317.6017.5022.0020.3426.5522.1737.5026.7351.0031.1767.6035.55
    JX250SL506HE-28216.8017.5522.9020.3426.8422.2039.9026.7451.6031.2068.1035.88
    JX360SL604GE-23320.1021.3126.2024.6630.4026.8543.1032.2259.1037.3878.2041.67
    JX375SL756HE-28325.2026.3033.1030.5139.3633.3056.6040.1176.2046.80101.3053.37
    JX390SL906GE-34330.1031.9939.2036.9945.4040.2965.4048.3688.2056.07117.2062.40
    JX4100SL1006HE-28434.0036.1044.9040.6852.6044.4073.9053.48101.0062.40135.1071.16
    JX3120SL1206FE-44337.1039.0248.0044.7656.2548.6079.2058.26105.9067.80140.1077.10
    JX4120SL1206GE-34439.1042.6651.2049.3260.1053.7285.7064.48116.8074.76155.1083.20
    JX4160SL1606FE-44419.2052.5063.3059.6874.3064.80104.8077.68141.1090.40186.50102.80
    JX5200SL2006FE-44561.2065.1079.2074.6092.4081.00130.9097.10176.52113.00233.20128.50
    JX6240SL2406FE-44673.1078.2095.2089.52111.2097.20156.80116.52211.20135.60278.90154.20


    机组供电380V/50HZ;

    名义制冷量及输入功率基于环境温度+32℃,冷凝温度+45℃,制冷剂R22;

    如果机组需要运行不同的蒸发温度或高/低的环境温度,请联系我们公司;

    所有的制冷量与输入功率参数单位均为KW,制冷量参数为经有效值,在考虑了管路损失后仅需对系统加多10%的余量。

    型号机组对外管路尺寸标准支管理球阀数量外形尺寸电子低液位报警重量电气参数机房通风量
    排气供液吸气排气供液吸气工作电流保险丝电流m&sup3;/h
    mmmmmmmmmmmmmmmmmm有N/无Nkg


    JX220SL16124211014508501700N50035441000
    JX224SL16124211014508501700N50042531200
    JX230SL16165411014508501700N60053661600
    JX240SL22165411014508501700N60062781800
    JX345SL22226711020508501700N85079992400
    JX250SL222267110205011001750N80078982400
    JX360SL28227911020508501700N850921152800
    JX375SL352*222*54122320011001750Y11001171463500
    JX390SL353*223*54133320011001750Y12001381734200
    JX4100SL353*223*54133410011001750Y14001561954700
    JX3120SL423*223*54133340012001750Y14001772215100
    JX4120SL423*223*54133410011001750Y16501842305600
    JX4160SL544*224*54144410012001750Y18002352946800
    JX5200SL544*284*67144470012001800Y22002943688500
    JX6240SL545*285*67155530012001800Y280035344110100

    所列机组对外管尺寸为标准机组对外管路尺寸,可依据客户需求定制。

    所有标准机组(R22)预先充注矿物油,404A、134A机组预先充注聚酯油。

    压缩机运转时会通过自身缸体向外散热,由于并联压缩机组位于机房内,故应保证足够的通风量以避免机房温度过高。

    当机房有多台机组时,应计算各台通风量之和。

    利来国际平台